Ohaus I150-S Indicator Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Waga Ohaus I150-S Indicator. Ohaus I150-S Indicator User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
Instruction Manual
I150 Electronic Indicator
Models I150-P and I150-S
Ohaus CorporationOhaus Corporation
Ohaus CorporationOhaus Corporation
Ohaus Corporation
29 Hanover Road
Florham Park NJ
07932-0900
Przeglądanie stron 0
1 2 3 4 5 6 ... 75 76

Podsumowanie treści

Strona 1 - Instruction Manual

Instruction ManualI150 Electronic IndicatorModels I150-P and I150-SOhaus CorporationOhaus CorporationOhaus CorporationOhaus CorporationOhaus Corporati

Strona 2

10RS-232 ConnectionsRS-232 ConnectionsRS-232 ConnectionsRS-232 ConnectionsRS-232 ConnectionsUsing a small screwdriver, connect theRS-232 interface cab

Strona 3 - Classifications

11Digital Output ConnectionsDigital Output ConnectionsDigital Output ConnectionsDigital Output ConnectionsDigital Output ConnectionsDigital outputs ar

Strona 4 - TABLE OF CONTENTS

12Turning the I150 ONTurning the I150 ONTurning the I150 ONTurning the I150 ONTurning the I150 ONAfter all connections have been made, plug in the pow

Strona 5

13Numeric Keypad;used to enternumeric valueswhen applicable.Switches display from one loadreceiver to another. Stepsbackward through menu se-lections.

Strona 6

14TO ACCESS THE MAIN MENU:TO ACCESS THE MAIN MENU:TO ACCESS THE MAIN MENU:TO ACCESS THE MAIN MENU:TO ACCESS THE MAIN MENU:Press FNCT, then press SETP.

Strona 7

15Resetto factorydefaultsALEnter value0, 1, 2 or 3StbEnter value0.5, 1 or 3Selectactive unitsAT0.5, 1, 3 orOFFCustom UnitsExp. MantissaEnter Entervalu

Strona 8 - Load Receiver Connections

16MAIN MENUMAIN MENUMAIN MENUMAIN MENUMAIN MENUDisplayed SubmenuDisplayed SubmenuDisplayed SubmenuDisplayed SubmenuDisplayed SubmenuDescriptionDescrip

Strona 9

17To select an item from a menu:To select an item from a menu:To select an item from a menu:To select an item from a menu:To select an item from a men

Strona 10

18SETUP SUBMENUSETUP SUBMENUSETUP SUBMENUSETUP SUBMENUSETUP SUBMENUThe Setup submenu is used to view or change the parameters outlined in the followin

Strona 11 - Digital Output Connections

19Legal For TradeLegal For TradeLegal For TradeLegal For TradeLegal For TradeThis parameter can be set to ON or OFF.Selecting ON automatically sets ce

Strona 12

2The exclamationpoint within the tri-angle is a warningsign alerting you ofimportant instruc-tions accompany-ing the product.NOTE:NOTE:NOTE:NOTE:NOTE:

Strona 13 - Key Functions

20Number of Load ReceiversNumber of Load ReceiversNumber of Load ReceiversNumber of Load ReceiversNumber of Load ReceiversThe I150 is configured for o

Strona 14

21Calibration UnitCalibration UnitCalibration UnitCalibration UnitCalibration UnitThe indicator can be calibrated usingpounds or kilograms; no other u

Strona 15

22GraduationsGraduationsGraduationsGraduationsGraduationsThis parameter specifies the incrementsin which the last digit of the display willcount, and

Strona 16 - How To Use Menus

23Linearization PointLinearization PointLinearization PointLinearization PointLinearization PointThis parameter is used when 3-point lin-earization is

Strona 17 - Load Receiver #1

24To select a parameter:Repeatedly press UPUP or DOWNuntil it is displayed,then press ENTER.SCALE SUBMENUMENUSCALE SUBMENUMENUSCALE SUBMENUMENUSCALE S

Strona 18 - SETUP SUBMENU

25Reset to Factory DefaultsReset to Factory DefaultsReset to Factory DefaultsReset to Factory DefaultsReset to Factory DefaultsThis parameter is used

Strona 19

26Stability RangeStability RangeStability RangeStability RangeStability RangeThe stability range specifies how much adisplayed weight may change (in g

Strona 20

27Unit SelectionUnit SelectionUnit SelectionUnit SelectionUnit SelectionThe I150 provides four weighing unitswhich may be used for weighing opera-tion

Strona 21 - Enter Full Scale Point

28Auto-Zero TrackingAuto-Zero TrackingAuto-Zero TrackingAuto-Zero TrackingAuto-Zero TrackingAuto-Zero tracking minimizes the effectsof temperature cha

Strona 22

29Entering a Conversion FactorEntering a Conversion FactorEntering a Conversion FactorEntering a Conversion FactorEntering a Conversion FactorConversi

Strona 23

3PREFACEPREFACEPREFACEPREFACEPREFACEThe I150 Electronic Indicator is a highly versatile device which is designed for a varietyof applications. It can

Strona 24 - SCALE SUBMENUMENU

30Conversion Factor ExamplesConversion Factor ExamplesConversion Factor ExamplesConversion Factor ExamplesConversion Factor ExamplesCustom unit conver

Strona 25

31Average Display CycleAverage Display CycleAverage Display CycleAverage Display CycleAverage Display CycleAverage display cycle is used for animalwei

Strona 26 - Stability Range

32Set PointSet PointSet PointSet PointSet PointSet point is used to enable checkweigh-ing, filling or emptying for operation. Ena-bling one of these m

Strona 27 - Unit Selection

33To Enter DRIBBLE and PREACT:To Enter DRIBBLE and PREACT:To Enter DRIBBLE and PREACT:To Enter DRIBBLE and PREACT:To Enter DRIBBLE and PREACT:1. With

Strona 28 - ENTERENTER

348. To change the value, use the nu-meric keypad.For emptying processes, make thedisplayed value negative by pressingFUNC then CLRR.9. To accept the

Strona 29

35Retain Zero DataRetain Zero DataRetain Zero DataRetain Zero DataRetain Zero Data“rEtAin” can be set to ON or OFF. Whenset to ON, zero data is saved

Strona 30 - 0.0625 = 0.625 x 10

36CALIBRATION SUBMENUCALIBRATION SUBMENUCALIBRATION SUBMENUCALIBRATION SUBMENUCALIBRATION SUBMENUThe calibration submenu is used for two purposes: To

Strona 31

37CalibrationCalibrationCalibrationCalibrationCalibrationBefore beginning, you must know thecalibration point that was entered in the“SEtUP” submenu,

Strona 32 - LED Indicators

383. The display will show “buSY” whilethe I150 reads the first calibrationpoint, and then show “C XXXX” indi-cating the value of a load which mustbe

Strona 33

397. Apply the required load to the loadreceiver, and then press ENTER.8. The display will show “buSY” whilethe I150 reads the last calibrationpoint.9

Strona 34 - StoreStore

4TABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSPAGEUNPACKING ...

Strona 35

40RS-232 SUBMENURS-232 SUBMENURS-232 SUBMENURS-232 SUBMENURS-232 SUBMENUThe RS-232 submenu is used to configure the interface communication parameters

Strona 36 - Example:

41To select a parameter:Repeatedly press UPUP or DOWNuntil it is displayed,then press ENTER.Baud RateBaud RateBaud RateBaud RateBaud RateBaud rate can

Strona 37

42Sample Size (APW)Sample Size (APW)Sample Size (APW)Sample Size (APW)Sample Size (APW)(for Auxiliary Sample Scale)(for Auxiliary Sample Scale)(for Au

Strona 38

43Non Printing Weight ValuesNon Printing Weight ValuesNon Printing Weight ValuesNon Printing Weight ValuesNon Printing Weight Valuesand Auto Print Tim

Strona 39

4411. Enter the desired interval in seconds( maximum of 255) using the numerickeypad, then press ENTR.12. Press UPUP or DOWN to scroll to“End”.13. P

Strona 40 - RS-232 SUBMENU

45To select display or block print:Press UPUP or DNDN to display thedesired setting, then press ENTR toreturn to the rS-232 submenu.Print Numeric Data

Strona 41

46EndEndEndEndEndYou must select “End” to exit the rS-232submenu.1. Press ENTER when “End” is dis-played.2. “rS-232” will be displayed and themain m

Strona 42

47Disabling Menu Changes forDisabling Menu Changes forDisabling Menu Changes forDisabling Menu Changes forDisabling Menu Changes forLegal For Trade In

Strona 43

48Hole PlugClosing the CoverClosing the CoverClosing the CoverClosing the CoverClosing the CoverWhen all connections and settings havebeen made, close

Strona 44

49WeighingWeighingWeighingWeighingWeighing1. Select the desired weighing unit .2. If necessary, press ZERO to obtain azero reading on the display.3. P

Strona 45

5PAGERS-232 SUBMENU ... 40Baud Rate ...

Strona 46

504. To view the combined weight of thematerial and the container (grossweight), press GROSS.Repeatedly pressing GROSS willcause the display to switch

Strona 47 - Disable Changes

51View/Enter Time and DateView/Enter Time and DateView/Enter Time and DateView/Enter Time and DateView/Enter Time and DateThe I150 is equipped with an

Strona 48 - Hole Plug

52Parts CountingParts CountingParts CountingParts CountingParts CountingParts counting enables you to place abatch of similar parts on the platformwhi

Strona 49 - Indicator

53Enter the number of pieces using thenumeric keypad, then press PCSS.The indicator will use the sample asa reference for counting.The sample may be a

Strona 50

54Subtractive Parts CountingSubtractive Parts CountingSubtractive Parts CountingSubtractive Parts CountingSubtractive Parts CountingThis method of par

Strona 51 - View/Enter Time and Date

55Parts Counting With An Auxiliary Sample ScaleParts Counting With An Auxiliary Sample ScaleParts Counting With An Auxiliary Sample ScaleParts Countin

Strona 52 - Parts Counting

56SetupSetupSetupSetupSetupRS-232 parameters for the I150, sample scale and printer/computer (if used) must beconfigured the same; baud rate, parity,

Strona 53

57CheckweighingCheckweighingCheckweighingCheckweighingCheckweighingCheckweighing enables you to compareunknown weights to a target weight. Byentering

Strona 54 - Subtractive Parts Counting

58Filling and Emptying ProcessesFilling and Emptying ProcessesFilling and Emptying ProcessesFilling and Emptying ProcessesFilling and Emptying Process

Strona 55 - RS-232 Connections

59TOLERANCE - set point 2TOLERANCE - set point 2TOLERANCE - set point 2TOLERANCE - set point 2TOLERANCE - set point 21. Enter the value using the nume

Strona 56

6UNPACKINGUNPACKINGUNPACKINGUNPACKINGUNPACKINGVerify that your indicator was shippedwith the following items:• I150-P or I150-S indicator• power cord•

Strona 57 - Checkweighing

60Emptying Processes:Emptying Processes:Emptying Processes:Emptying Processes:Emptying Processes:1. Enter a value equal to 10% of thetarget weight for

Strona 58

61Animal WeighingAnimal WeighingAnimal WeighingAnimal WeighingAnimal WeighingBefore beginning this procedure, makesure the number of sample readings t

Strona 59 - Suspended

62Storing Tare Values With ID Codes:Storing Tare Values With ID Codes:Storing Tare Values With ID Codes:Storing Tare Values With ID Codes:Storing Tare

Strona 60

63Using Stored Average Piece Weights:Using Stored Average Piece Weights:Using Stored Average Piece Weights:Using Stored Average Piece Weights:Using St

Strona 61

64The following will be output via theRS-232 interface:XX:XX:XX (time) *XX/XX/XX (date) *ID: XXXXXX (ID code)IN: X.XXXX lb (original load)OUT: X.XXXX

Strona 62 - Press RECALL

65RS-232 INTERFACERS-232 INTERFACERS-232 INTERFACERS-232 INTERFACERS-232 INTERFACETerminal Block ConnectionsTerminal Block ConnectionsTerminal Block C

Strona 63

66RS-232 COMMAND TABLERS-232 COMMAND TABLERS-232 COMMAND TABLERS-232 COMMAND TABLERS-232 COMMAND TABLE< or > switch load receivers; if dual lo

Strona 64

67RS-232 COMMAND TABLE (Continued)RS-232 COMMAND TABLE (Continued)RS-232 COMMAND TABLE (Continued)RS-232 COMMAND TABLE (Continued)RS-232 COMMAND TABLE

Strona 65 - RS-232 INTERFACE

68Output FormatsOutput FormatsOutput FormatsOutput FormatsOutput FormatsData output can be initiated in one of three ways: (1) By pressing PRINT; (2)

Strona 66

69Block Data Output:Block Data Output:Block Data Output:Block Data Output:Block Data Output:When “bLoc” is selected for “Print” in the rS-232 submenu,

Strona 67

7INSTALLATIONINSTALLATIONINSTALLATIONINSTALLATIONINSTALLATIONPower ConnectionsPower ConnectionsPower ConnectionsPower ConnectionsPower ConnectionsUsin

Strona 68 - Output Formats

70SYMPTOMUnit will not turn on.Cannot rezero indicator,or will not re-zero whenturned on.Center of Zero display in-dicator erratic or does notappear w

Strona 69

71SYMPTOMUnable to tare (tare keyor RS232 command)Unable to tare (keypadnumeric entry)Unable to retrieve storedID codes and data.Excessive weight read

Strona 70 - TROUBLESHOOTING

72Error CodesError CodesError CodesError CodesError CodesErr 0: Invalid memory checksum. Checksum is verified every time I150 is turnedon. Check setup

Strona 71 - TROUBLESHOOTING (Cont’d.)

73SPECIFICATIONSSPECIFICATIONSSPECIFICATIONSSPECIFICATIONSSPECIFICATIONSModel NumbersModel NumbersModel NumbersModel NumbersModel Numbers I150-P and

Strona 72 - Error Codes

74REPLACEMENT PARTSREPLACEMENT PARTSREPLACEMENT PARTSREPLACEMENT PARTSREPLACEMENT PARTSOHAUSPART NO.Membrane Switch Panel 90835-00Display Filter Windo

Strona 73 - SPECIFICATIONS

75CARE AND MAINTENANCECARE AND MAINTENANCECARE AND MAINTENANCECARE AND MAINTENANCECARE AND MAINTENANCEI150 indicators are washdown units designed for

Strona 74

76Ohaus Corporation29 Hanover Road,Florham Park, NJ 07932, USATel: (201) 377-9000,Fax: (201) 593-0359With offices worldwide.P/N 77223-01 R1099 © Oh

Strona 75

86. After the connections have beenmade, fasten two cable ties (includedin the accessory kit) around the powercord as shown in the diagram. Thecable t

Strona 76

9Installing “Gain Setting”Installing “Gain Setting”Installing “Gain Setting”Installing “Gain Setting”Installing “Gain Setting”Shorting JumpersShorting

Komentarze do niniejszej Instrukcji

Brak uwag